A kind
|
Form name
|
Input
|
The direct current output
|
Load
|
A supporting power supply
|
Accuracy
|
Conversion
|
AC Current
|
AGP-L
|
AC 5, 1A
|
0-100mV
0-1V
0-5V
0-10V
1-5V
0-1mA
0-10mA
4-20mA
|
600 Ω ...∞
600 Ω ...∞
600 Ω ...∞
600 Ω ...∞
600 Ω ...∞
0 - 10kΩ
0 - 1kΩ
0-550 Ω
|
DC 24V
AC100/110V
AC200/220V
DC100/110V
|
0.5%
|
I rectify the mean
limiter i
|
AGP-E(L)
|
Actual value operation
limiter
|
Resistance temperature
|
CGP
|
- 200 degrees Celsius - +500 degrees Celsius
|
0.5%
|
PT, JPT
|
Isolator
|
DGP
|
A DC voltage, a direct current
|
0.25%
|
|
DGP-L
|
limiter i
|
High speed
Isolator
|
DGP-F
|
|
DGP-FL
|
limiter
|
Reverse
Isolator
|
DGP-R
|
|
DGP-RL
|
limiter
|
Absolute value output
Isolator
|
DGP-V
|
0.25%
|
|
DC - pulse
|
EGP
|
A DC voltage, a direct current
|
0.005-1000Hz
|
0.5,5,50mSEC
|
0.5%
|
|
EGP-Z
|
667-10kHz
|
|
|
|
Frequency
|
FGP
|
45-65Hz
|
0-100mV
0-1V
0-5V
0-10V
0-5V
0-1mA
0-10mA
4-20mA
|
600 Ω ...∞
600 Ω ...∞
600 Ω ...∞
600 Ω ...∞
600 Ω ...∞
0 - 10kΩ
0 - 1kΩ
0-550 Ω
|
0.5%
|
|
Thermocouple
|
JGP
|
1,200 degrees Celsius
|
0.5%
|
K,E,J,T,R,B,S,N
|
Potentio meter
|
KGP
|
100 Ω - 10kΩ
|
0.5%
|
|
KGP-7
|
〃 2 line type
|
|
|
LMP
|
A DC voltage, a direct current
|
0.5%
|
|
D istributor
|
PGP
|
DC 4-20mA
|
0.25%
|
Supply DC24V
|
PGP-C
|
0.5%
|
There is no insulation
|
Kaiping operation device
|
QGP
|
A DC voltage, a direct current
|
0.5%
|
|
Number of revolutions
(A pulse)
|
TGP
|
Voltage / pulse 30kHz
|
0.5%
|
|
TGP-D
|
It is with a sensor power supply
|
TGP-S
|
Voltage / pulse 20kHz
|
A slow pulse
|
Subtraction device
|
UGP-(L)
|
A DC voltage, a direct current
|
0.5%
|
limiter
|
AC Voltage
|
VGP-(L)
|
AC 150, 300V
|
0.5%
|
I rectify the mean
limiter
|
VGP-E(L)
|
Actual value operation
limiter
|
Adder
|
WGP-(L)
|
A DC voltage, a direct current
|
0.5%
|
limiter
|
Multiplier
|
XGP
|
A DC voltage, a direct current
|
0.5%
|
|
Division device
|
YGP
|
A DC voltage, a direct current
|
0.5%
|
|
Primary delay
|
RAGP
|
A DC voltage, a direct current
|
0.5%
|
|
Pulse
An isolator
|
RBGP
|
ON, an OFF pulse
A voltage pulse
|
A voltage pulse
An open drain
|
|
|
|
RBGP-D
|
It is with a sensor power supply
|
Road cell
|
RLGP
|
1mV/V
1.5mV/V
2mV/V
5mV/V
10mV/V
20mV/V
|
0-100mV
0-1V
0-5V
0-10V
1-5V
0-1mA
0-10mA
4-20mA
|
600 Ω ...∞
600 Ω ...∞
600 Ω ...∞
600 Ω ...∞
600 Ω ...∞
0 - 10kΩ
0 - 1kΩ
0-550 Ω
|
DC 24V
AC100/110V
AC200/220V
DC100/110V
|
0.25%
|
|
Resistance - direct current
|
RIGP
|
50 Ω - 10kΩ
|
0.5%
|
|
Input choice
|
RFGP
|
A DC voltage, a direct current
|
0.25%
|
|
linearlizer
|
LMP
|
A DC voltage, a direct current
|
0.25%
|
A storehouse in the microcomputer
|
Analog storage device
|
MMP
|
A DC voltage, a direct current
|
0.25%
|
A storehouse in the microcomputer
|
Peak holder
|
NMP
|
A DC voltage, a direct current
|
0.25%
|
A storehouse in the microcomputer
|
Analog
Backup
|
RKMP
|
A DC voltage, a direct current
|
0.25%
|
A storehouse in the microcomputer
|
A power supply
|
SGP
|
|
DC24V 100mA
|
|
AC100/110V
AC200/220V
|
|
|
感溫素子
|
ZGP-A
|
|
|
|
|
|
JGP use
|
Current protection device
|
ZGP-B
|
5A, 1A
|
|
|
|
|
AGP use
|
ZGP-D
|
I am for + input
|
DGP use
|
ZGP-D2
|
I am for ± input
|
DGP use
|
A shunt
|
ZGP-C
|
100-360mA
|
|
|
|
|
DGP use
|